Thermal Shock Test Chamber

Home > Products > Environmetal Test Chamber > Thermal Shock Test Chamber

thermal shock test chamber

Brand : KUNLUN
Model :
Description : thermal shock test chamber, is applicable to test temperature endurance of material structure and composite materials under a rapid shift from extremely high temperature to a extremely low temperature or reverse, so as to find in shortest time the chemical changes or physical damages caused by thermal expansion and contraction.
INQUIRE NOW!

Description

thermal shock test chamber

rubber, electronics etc, is applicable to test temperature endurance of material structure and composite materials under a rapid shift from extremely high temperature to a extremely low temperature or reverse, so as to find in shortest time the chemical changes or physical damages caused by thermal expansion and contraction.

 

thermal shock test chamber Standards met: GB/T2423.1.2,GB/T10592-2008,GJB150.3T, etc.

 

Parameters of the thermal shock test chamber

 

Article No

Air-cooled/water-cooled

TC50

TC80

TC120

TC150

TC225

TC408

TC800

TC1000

Controller

Imported LCD touch screen controller(Japan OYO/HONEYWELL)

Working tank temperature range

-40-150

-55-150

-70-150

temperature recovery time

Within 5min

High temperature tank temperature

60-200

60-200

60-200

Low temperature tank

-65-10

-70-10

-80-10

High and low temperature exposure time

+15030min

+15030min

+15030min

-4030min

-5530min

-6530min

Interior dimension

(cm)

W

40

50

60

60

50

60

80

100

H

D

Interior material

SUS304 stainless steel

Exterior material

stainless steel

Power supply

AC380V±10%50HZ Three-phase four-wire + protective conductor

Product specifications: 

1.Mechanical structure:

   A. The thermal Shock Chamber  meets the thermal cycling reliability test specifications (GJB150-2002, CNS, MIL, IEC, JIS). 

   B. Test samples are placed in the shelves with Japanese high torque linear motor driving the valve of the storage area to guide air circulation, meeting the purpose of testing the average temperature in the cold and heat temperature test.

   C. Special design is adopted by thermal shock chamber to save space and get moderate operate altitude. So it is easy for maintenance of thermal shock chamber.

   D. The insulating layer consists of anti-fire PU and high density fiber cotton to acquire best performance. In addition, the new design of K-type anti-sweat duct system is used to make the instrument more precise.

   E. Two groups of adjustable stainless steel shelves is available in the test area.

   F. High load pulleys are installed in the bottom of the machine to facilitate the movement of the machine.

   G High-cold-resistant stainless steel has the ability of high tightness even in the serious temperature conditions.

 

2.Refrigeration and temperature control system:

   A. It is equipped with the automatic and manual defrost system;

   B. U-type fin-speed heater;              

   C. K-type inner spiral refrigerant copper tube;

   D. A France Tecumseh high-efficiency and low-noise compressor;

   E. Slope type Fin-tube evaporator;

   F. Original imported electromagnetic valve, dry filter, capillary and other frozen components;

   G. Water-cooled condenser;

   H. A high quality and environmental protection R404a/R23 refrigerant;

   I. A France Tecumseh semi-hermitic compressor is adopted in the refrigeration system to acquire binary refrigerating and rapid effect.

   J. The multi-wing circulating fan is adopted in the storage area to improve the average temperature efficiency by forcing air flow.

   K. P.I.D and SSR microcomputer are used in the hot-and-cold area and the test area to make automatic calculation of high control precision for temperature control

 

3.Air circulation system and drainage system:

   A. The drainage system adopts the volute drainage and U-TRAP deposition apparatus.

   B. Multi-wing centrifugal circulating fan is connected to the power saving motor made in Japan through the stainless steel long axis.

   C. Air supply: horizontal diffusion curved vertical heat exchange loop.

 

4.Description of control system:

   A. Automatic circulation shock and manual selective shock are all available in this system.

   B. The color touch screen is used in the controller for convenience setting and microcomputer SSR used for automatic temperature control.

   C. Two area or three area shock are all available as well as forward or reverse start.

   D. Maximum cycle up to 9999 times;

   E. If the instrument fails to work, the instrument will be shut down automatically with warning signals.

   F. If you wants to set high or low temperature individually, time control up to 999H59M is available.

 

5. Security protection system:

   A. Thermal Shock Test Chamber  is equipped with no fuse protection switch.

   B. Under-voltage protection and translation protection are available in the control system.

   C. There is a over-temperature protection switch.

   D. Overload protection device and high-and-low pressure protection switch are equipped in the refrigeration compressor.

   E. The fan motor and air-duct gate motor are also in the overload protection.

   F. The instrument is equipped with the self-detection function to find the failure point for easy maintenance.

 

 

Other products

>>